Overview
OverviewThe Allen-Bradley DH+ Device Driver was designed specifically for use with 32 bit OPC Server products and supports Allen Bradley SLC 500 Family and PLC5 series PLC's. Address ranges are open to support future models of these series of PLCs.
Note: Does not require the use of RSLinx licenses.
This driver is part of the Allen Bradley OPC Server Suite. Purchasing either the Allen Bradley PLC5/SLC505 Ethernet OPC Server, the Allen Bradley Unsolicited Ethernet OPC Server, the Allen Bradley ControlLogix Ethernet OPC Server, the Allen-Bradley Data Highway Plus OPC Server or the Allen Bradley DF1 OPC Server driver entitles you to all of the drivers.
Devices
Supported Devices| Device | Note |
| PLC 5/10 | |
| PLC 5/15 | |
| PLC 5/20 | |
| PLC 5/20E | |
| PLC 5/25 | |
| PLC 5/30 | |
| PLC 5/40 | |
| PLC 5/40E | |
| PLC 5/60 | |
| PLC 5/80 | |
| PLC 5/80E | |
| SLC 5/01 | |
| SLC 5/02 | |
| SLC 5/03 | |
| SLC 5/04 |
Features
Specific Driver Features
SpecificSpecific Driver Features
GeneralGeneral Driver Features
ClientOPC Client Support
DDE Client Support
3rd Party Client Support To see a list of HMI's and Clients that we support go to our HMI / Client Support page. |
Required
Required Software and HardwareSupported Operating Systems
- Windows 2000 (SP4 or greater) (32 bit and 64 bit)
- Windows Server 2003 (SP2 or greater) (32 bit and 64 bit)
- Windows XP (SP2 or greater)
- Windows Vista Business/Ultimate (32 bit and 64 bit)
- Windows Server 2008 (32 bit and 64 bit)
PC Hardware
Minimum- 400 Mhz Pentium CPU
- 128 Megs of RAM
- 100 Megs of Free Hard Drive Space
Recommended
- 600 Mhz Pentium CPU
- 512 Megs of RAM
- 100 Megs of Free Hard Drive Space
Hardware Requirements
- For Device and Hardware Requirements see the Devices tab.
- Hardware Accessories
Protocol
Communication Protocol- Allen-Bradley DH+ / DH485
VB
Visual Basic- KEPServerEX Visual Basic OPC Client
- Complex and Simple Visual Basic OPC Client Examples
- Using Modems and Visual Basic with KEPServerEX.
- Download the Modem and VB Example with Source Code
- Knowledge Base
Help
Help/LinksRevisions
Allen-Bradley Data Highway Plus OPC Driver Revisions| Driver updates below coincide with Server Release V4.280.435.0 (04/30/08) |
| Allen-Bradley DH+ (V4.30.50.0) |
| - Fixed issue where local station address (channel property) could not be changed (in property sheet mode) when board type is PCMK/B and network is DH-485. |
| Driver updates below coincide with Server Release V4.270.416.0 (09/27/07) |
| All Drivers |
| - Fixed issue where server menu buttons like 'New', 'Open', 'Exit' would become permanently disabled when attempting to perform auto tag generation on a driver that had missing runtime dependencies. - Fixed issue that could occur when multiple items with the same scan rate are read by exception and another item is added/asynchronously read/removed at that same rate. This issue resulted in stale data for those tags read by exception. |
| Driver updates below coincide with Server Release V4.264.401 (06/01/07) |
| All Drivers |
| - Fixed issue in the driver library where it was possible to delete a tag prior to stopping it. This would result in the accessing of invalid memory which could eventually result in an exception that would prevent a channel from processing any tags. |
| Allen-Bradley DH+ (V4.27.45) |
| - Fixed issue with error dialog box when an invalid station address was entered. - Fixed issue where the driver allowed the station address to exceed the maximum for DH485 network. - Fixed the issue where some interface card options displayed incorrectly in channel properties. |
| Driver updates below coincide with Server Release V4.210.367 (11/17/06) |
| All Drivers |
| - Fixed issue where a rapid sequence of item add, sync read, and item remove requests could result in bad OPC quality for some items included in a block sync read and/or sync read timeouts. - Fixed issue with Unsolicited UDP Mode Ethernet Encapsulation mode, where driver would stop receiving unsolicited messages after sending a message. |
| Allen-Bradley DH+ (V4.20.37) |
| - Increased address ranges for B,T,C,R,N,F,A,D, and BT files to 2000 elements for PLC-5. |
| Driver updates below coincide with Server Release V4.190.341 (11/23/05) |
| Allen-Bradley DH+ (V4.03.29) |
| - Updated float arrays to return 0 for any item that contains an invalid IEEE floating point value. - Fixed driver load issues related to KTX and KT cards. |
| Driver updates below coincide with Server Release V4.180.338 (8/12/05) |
| Allen-Bradley DH+ (V4.03.23) |
| - Fixed ASCII (A File) issue where the last element of an array would always read NULL for arrays of even length size starting at an odd by the offset. |
| Driver updates below coincide with Server Release V4.160.316 (2/11/05) |
| Allen-Bradley DH+ (V4.01.17) |
| - Fixed issue with multiple PKTXD cards. - Added support for accessing Channel 2 of a PKTXD card. - Added device property (PKTXD Channel ID) to determine which channel to use on a PKTX card. |
| Driver updates below coincide with Server Release V4.150.304 (11/12/04) |
| Allen-Bradley DH+ (V4.00.7) |
| - New Driver |